13

Figure 18 shows a Line Splitter L cascaded to a Receiver DCL.

200m/660ft

Receiver DCL

Player

Transmitter/Broadcaster

Line Splitter Long

100m/330ft

Receiver

DCL

Receiver

DCL

300m/1,000ft

300m/1,000ft

Figure 18 Receiver DCL + Line Splitter L

Figure 19 shows two Receiver DCL units cascaded to 300m/1,000ft. (You can
cascade up to 10 levels of Receiver DCL / Line Splitters).

100m/330ft

200m/660ft

Receiver DCL

Player

Transmitter/Broadcaster

Receiver DCL

Figure 19

Cascaded Receivers DCL


6. Pre-installation guidelines

Place cables away from fluorescent lights, air conditioners, and machines that are
likely to generate electrical noise.

Twisted Pair wiring - installation tips

·

The minimum recommended bend radius for Twisted Pair cable is 4 cm.

·

Don’t twist the Twisted Pair cable.

·

Don’t over tighten wire ties.

·

Don’t bend the Twisted Pair cable more than 90 degrees.

·

Don’t use a stapler for installation.

·

Don’t stretch or apply a pull-force greater than 11 kg.