General information – Multiquip submersible pumps px400 User Manual

Page 11

Advertising
background image

cx400/px400 Sub. pump • operation and partS manual — rev. #1 (12/03/10) — page 11

general infOrMatiOn

The Multiquip Model CX400 and PX400 submersible pumps

are designed to pump water and is used for the draining

(dewatering) of well casings construction sites, coffer dams,

manholes, transformer vaults and excavations.
Its slim design, only 10 inches (25.4 cm.) in diameter allows

it to fit easily inside casings and eliminates the need for

larger, more costly casings. The pump is powered by a 1/2

HP, 115-volt, single-phase motor for easy starting with a

small 2,500-watt generator.
This rugged submersible pump is loaded with features

such as:

„

tHermal overload protection - Automatically

shuts off the motor should it reach an unsafe operating

temperature.

„

HeavY-dutY liFting Handle - Provides and

convenient and safe location to attach a lifting device.

„

Strain-relieF protector - Provides added safety

in the event the operator should try lifting the pump from

the electrical cord.

„

replaceable diScHarge port - Provides easy

maintenance and lower repair costs.

„

double oil-lubricated Seal - provides positive

lubrication if the pump should be left running dry. This

helps prevent damage in the event the pump is run dry

for short periods of time.

„

impeller - Abrasion resistance plastic minimizes wear

and extends impeller life.

„

pump caSing - High strength plastic design makes

pump a great choice in corrosive environments. Ideal for

use in marine and certain chemical applications.

If the pump was used to pump water containing mud, silt,

use clean water to flush out the pump after each use.
do not allow the pump to run dry for an extended period

of time, as this will damage the pump. During maintenance,

dry running is permissible but only for a few seconds.
never lift the pump by its electrical power cord. alWaYS

lift the pump by its carrying handle or attach a rope to the

carrying handle.
A pump fully submerged in liquid will not freeze, unless

the liquid freezes.

do not allow a partially submerged

pump to freeze. The expansion of water freezing in the

volute may crack the pump, causing expensive repairs. If

there is any danger of the pump being subjected to freezing

temperatures, Lift the pump from water and allow it to drain

thoroughly.
If the pump jams or the pump rotor locks for any reason,

disconnect the pump from the power source immediately.

Allowing the pump motor to cycle

on and oFF under an

overload condition can burn out the motor.
When replacement of nuts and bolts is required, use only

recommended parts as referenced in the parts section of

this manual. This pump uses metric threads.

do not use

English measurement threads.

Advertising