direct pOwer OperatiOn

direct power operation

The CX400/PX400 submersible pumps can be configured to operate by direct power (Figure 4) or connected to a control

box (Figure 10) utilizing float switches. When the pump is connected directly to a 1Ø, 115 VAC, 60 Hz power source, the

pump will operate soon as power is applied. It is suggested that a quick disconnect switch be installed as a means of

turning the power on and off.
When operating the pump using direct power (no control box), the pump must be monitored at all times. Failure to monitor

the pump during operation could lead to

severe pump damage should the pump encounter problems such as a stuck

impeller or not fully immersed in water.

Figure 4. Direct Power Application

.

LIFTING

ROPE

2-INCH

DISCHARGE

HOSE

SUPPORT

PLATFORM

CARRYING

HANDLE

POWER

CORD

115 VAC

POWER

PLUG

GREEN

BLACK

EXTERNAL

1Ø 115 VAC, 60 Hz

POWER SOURCE

CIRCUIT

BREAKER

L

N

WHITE

GND. BUS

SUBMERSIBLE

PUMP