Maintenance

Cleanup

1. Wipe off any mud or debris that might have attached

itself to the pump.

2. If the pump was used to pump mud, grit or silt, flush

vigorously with clean water.

3. Store pump in a clean dry place away from dirt and

debris.

lubrication

To check the lubrication oil level of the mechanical seal

perform the following:
Checking Lubrication Oil Level (2,000 hours/6 months)

1. Lay pump flat on its side (PX400 only) as shown in

Figure 17.

Figure 17. Checking Lubrication Oil Level

2. Using a screwdriver, remove oil plug.
3. Visually inspect oil plug hole to verify that oil cavity is

full enough to cover seal spring.

4. When reinstalling oil plug, apply teflon tape to prevent

leaking.

REMOVE

PACKING

REMOVE

OIL

PLUG

LAY PUMP FLAT

ON ITS SIDE

SUBMERSIBLE

PUMP

PX400

NOTICE

Refer to Figure 21 for the location of oil plug. for

the CX400 submersible pump. Pump must be dis-

assembled to gain access to oil plug. When adding oil

to the CX400 pump, pump must be turned upside down.

Changing Lubrication Oil (4,000 hours/12 months)

1. If lubrication oil level is low, block the oil fill opening

with a finger and lay pump on its side (Figure 18) to

drain oil into a small container.

Figure 18. Draining Lubrication Oil

2. Use a funnel (Figure 19) and fill oil cavity with Fluid

Paraffin P70 lubrication oil or equavalent. Pump oil

cavity capacity is 175 cc. Fill to 75-80% capacity to

allow for expansion. Replace lubrication oil every 12

months (4,000 hours) or as needed.

Figure 19. Adding Lubrication Oil