Operation, Hose connections, Attaching lifting rope – Multiquip submersible pumps px400 User Manual

Page 17: Pump power connections (no control box)

Advertising
background image

cx400/px400 Sub. pump • operation and partS manual — rev. #1 (12/03/10) — page 17

Hose connections

1. Connect a 2-inch hose to the discharge port on the

pump as shown in Figure 11. Make sure that hose is

attached correctly to the discharge port.

attaching lifting rope

1. Attach a suitable lifting cable (rope) to the carrying

handle (Figure 11) on the pump and lower the pump

into place. For applications where there is an excessive

amount of mud, grit or silt, the use of a support platform

is desirable. When pumping water from swimming pool

type applications where there is little or no debris, the

support platform is not required.

Figure 11. Submersible Pump

Upright Position (Correct)

2. Make sure the pump is always placed in an upright

position (Figure 11, and not tilted (Figure 12). Never

position the pump directly on a soft, loose bottom.

Remember to attain maximum pumping capacity and

prevent excessive wear. Position the pump so it will

not burrow itself into sand or clay.

LIFTING

ROPE

2-INCH

DISCHARGE

HOSE

SUPPORT

PLATFORM

CARRYING

HANDLE

POWER

CORD

115 VAC

POWER

PLUG

GREEN

BLACK

EXTERNAL

1Ø 115 VAC, 60 Hz

POWER SOURCE

CIRCUIT

BREAKER

L

N

WHITE

GND. BUS

SUBMERSIBLE

PUMP

OperatiOn

Figure 12. Submersible Pump

Tilted Position (Incorrect)

pump power connections (no control box)

1. Make sure circuit breaker supplying power to pump

motor is in the

oFF position.

2. Insert the power cable plug (Figure 11) into the

appropriate power source receptable. The correct

source voltage for this pump is 115 VAC, 60 Hz,

single-phase.

3. If all of the pump's electrical requirements have been

met, place the circuit breaker or power ON/OFF switch

in the

on position.

4. Wait a few seconds and water should begin to flow

from the discharge hose.

5. If water is not flowing from the discharge hose or not

flowing freely after a few minutes, place the circuit

breaker or ON/OFF switch in the

oFF position and

check the system for leaks.

SUBMERSIBLE

PUMP

NOTICE

When connecting the pump directly to a power source

(no control box), it is recommeded that personnel

monitor the pump while in operation. Severe pump

damge can occur if left unattended.
For unattended operation Multiquip recommends the

use of the CB3 control box.

Advertising