Specification – Multiquip submersible pumps px400 User Manual

Page 9

Advertising
background image

cx400/px400 Sub. pump • operation and partS manual — rev. #1 (12/03/10) — page 9

specificatiOn

1.

motor rotation – Upon start-up, the pump "kicks" in the opposite direction of motor rotation. The correct rotation is

counterclockwise (CCW) as viewed from the impeller end of the pump.

2.

mechanical Seal oil – Use Paraffin P70 oil lubricant. Fill oil cavity 75% to 85% full (allow air space for expansion).

3.

control box - For unattended operation use CB3 Control box (Table 2).

table 1. Specifications

Model

CX400/PX400

Type

Submersible Trash Pump

Motor Type

Condenser Start

Condenser Drive

Impeller

Plastic

Suction & Discharge Size

2 in. (50 mm)

Maximum Pumping Capacity

72 gallons/minute/(273 liters/minute)

Max Head

34 ft. (10.3 meters)

Power

1/2 HP (.37 kw)

Voltage Phase

1Ø 115 V

Starting Amps

35.4

18.4

Running Amps

7

6.2

Control Box Required

NO (See Note 3)

Temperature Range

32° - 104°F (0° - 40°C)

Thermal Overload Protection

YES

Rotation

CCW (See Note 1)

Mechanical Seal Oil Capacity

15.54 in

3

(255 cc)

(See Note 2)

10.67 in

3

(175 cc)

(See Note 2)

Power Cable Length

19 ft (approximately 6 m)

Dry Net weight

21.4 lb (9.7 kg)

18.3 lb (8.3 kg)

Table 2. control box Specifications

Model

voltage type

ul/cSa

listed

thermal overload

Protection

Float Switch

Capability

CB3

115 VAC, 60 Hz Single Phase

YES

NO

YES

Advertising