ITT SMART SWITCH 801P5 User Manual

Page 43

Advertising
background image

Page 39 801P5 Smart Switch

TM

Range

No.

Operating

Range

bar

Increasing

Range

bar

Deadband

Percent of

Full Scale

Minimum

Decreasing

Setpoint

bar

Max

Operating

Pressure

bar

Proof

Pressure

bar

22

0 - 350

mB

7 - 350

mB

1-99

3.5 mB

0.86

1.7

24

0 - 1000

mB

20 - 1000

mB

1-99

10 mB

2.6

5.1

25

0 - 2

0.04 - 2

1-99

0.02

5.2

10.3

27

0 - 6.5 0.013 - 6.5

1-99

0.065

17.2

34.4

29

0 - 17

0.34 - 17

1-99

0.17

43.1

51.7

31

0 - 35

0.7 - 35

1-99

0.35

103

103

32

0 - 65

1.3 - 65

1-99

0.65

172

206

34

0 - 200

4 - 200

1-99

2

206

344

Range

No.

Operating

Range

in H

2

O

Increasing

Range

in H

2

O

Deadband

Percent of

Full Scale

Minimum

Decreasing

Setpoint

in H

2

O

Max

Operating

Pressure

psig

Proof

Pressure

psig

72

0 - 100

2 - 100

1-99

1

12.5

25

74

0 - 415 8.3 - 415

1-99

4.15

37.5

75

Total Accuracy

± 0.2% F.S.O., including linearity, hysteresis, repeatability, and
temperature

Advertising