5.5.2.3. The Invalid Access Lockout Feature
When properly configured and enabled, the Invalid Access Lockout feature

will watch all login attempts made at all CMS-6R4 ports. If a given port

exceeds the selected number of invalid attempts specified for that port, then

that port will be automatically disabled for a user-defined length of time.
When an Invalid Access Lockout occurs, you can either wait for the Lockout

Duration period to elapse (after which, the CMS-6R4 will automatically

reactivate the port), or you can issue the /UL command (type

/UL and press

[Enter]) via the Text Interface to instantly unlock all CMS-6R4 serial ports.

Notes:

• The Invalid Access Lockout Feature is available to the Serial RS232

Ports, the Internal Modem Port, and the Network Port.

• When a Port is locked, an external modem connected to that port

will not answer.

• When a given CMS-6R4 serial port is locked, the other serial ports

will remain unlocked, unless the Invalid Access Lockout feature has

been triggered at those other ports.

• If any one of the CMS-6R4’s logical network ports is locked, all

other network connections to the unit will also be locked.

• All invalid access attempts at the CMS-6R4 Network Port are

cumulative (the count for invalid access attempts is determined

by the total number of all invalid attempts at all available logical

network ports.) If a valid login name/password is entered at any of

the logical network ports, then the count for all CMS-6R4 logical

network ports will be restarted.

• In the Text Interface, Invalid Access Lockout parameters are defined

via a submenu of the Telnet Port Parameters menu. In the Web

Browser Interface, Invalid Access Lockout parameters are defined

using the Telnet Parameters Menu as described in Section 5.5.2.2.

The Telnet Parameters Menu (Web Browser Interface) and Invalid Access

Lockout Menu (Text Interface) allow the following parameters to be defined:

Lockout Enable: Enables/Disables the Invalid Access Lockout feature.

(Default = Off.)

Lockout Attempts: The number of invalid attempts required to activate

the Invalid Access Lockout feature. (Default = 9.)

Lockout Duration: The length of time ports will remain locked when

an Invalid Access Lockout occurs. If the duration is set at “Infinite”, then

ports will remained locked until the /UL command is issued. (Default =

30 Minutes.)