background image

NIGHT TIME

DELAY START

OPERATION

SAMPLE ONE STAGE PROGRAM
(To be completed and ready to cast in 24 hours)

HEAT RATE

TEMP

HOLD TIME

STAGE 1

STAGE 2

STAGE 3

STAGE 4

24:00

10°F (6°C)

1600°F (871°C)

1:00

NO

NO

NO

*

*

*

*

*

*

* Though any number may appear, the unit is deactivated when “NO” is selected for the HEAT RATE.

NOTE: To turn off STAGE 2,3 and 4, select “NO” for the HEAT RATE in STAGE 2.

Press NIGHT TIME (DELAY START). Infinity automatically turns on at the correct time to complete the program
and be ready to cast in 24 hours.

SAMPLE TWO STAGE PROGRAM
(To start immediately)

HEAT RATE

TEMP

HOLD TIME

STAGE 1

STAGE 2

STAGE 3

STAGE 4

10°F (6°C)

1600°F (871°C)

1:00

NO

NO

*

*

*

*

* Though any number may appear, the unit is deactivated when “NO” is selected for the HEAT RATE.

20°F (11°C)

600°F (316°C)

30

NOTE: To turn off STAGE 3 & 4, select “NO” for the HEAT RATE in STAGE 3.

To start immediately, press START / STOP.

Follow the same programming procedures if a three or four stage program is desired.