CAUTION: The INFINITY should be serviced only by qualified service technicians. Be sure to
unplug the power cord and wait for the furnace to cool before performing any service opera-
tion. For help with operating or servicing your Jelrus equipment, please call Jelrus any time
between 9:00am and 5:00pm Eastern time.

Toll Free:

1-800-JELRUS-1

In New York:

1-516-942-0202
FAX 1-516-433-7684

TEMPERATURE CALIBRATION
Infinity Multi-Stage Burnout Furnaces come complete with temperature Calibration Tablets (2) which accurately melt
at 1500°F (816°C). (Re-Order Calibration Tablet Kit - PN 15291).

Your Infinity is factory calibrated. It is not necessary to re-calibrate on installation. If it becomes necessary to
re-calibrate in the future, use the following calibration procedure.

Temperature Calibration with Calibration Tablets (Figure 3)

1. Place a short metal casting ring towards the front center of the chamber.

2. Place a ceramic tray or a small piece of casting ring lining material on top of the ring. Place a tablet

in the center of the tray.

3. Program the Infinity as follows:

HEAT RATE

TEMP

HOLD TIME

STAGE 1

FULL

1200°F (649°C)

0:05

STAGE 2

25°F (14°C)

1700°F (927°C)

0:00

STAGE 3

NO

*

*

STAGE 4

NO

*

*

*Though any number may appear, the unit is deativated when “NO” is selected for HEAT RATE.

4. Close the furnace door and press START / STOP.

5. When the furnace temperature attains 1400°F (760°C) as indicated on the Main display, open the

furnace door slightly and begin to check for the melting of the of the tablet. Continue to do this at each
25°F (14°C) interval, opening the furnace door just enough to determine at a quick glance if the
tablet has begun to liquify at the edges.

SERVICE

CLEANING INSTRUCTIONS
Clean exterior of furnace only by wiping unit with a damp cloth coated with a mild non abrasive cleaner.