SPECIFICATIONS

INFINITY M

INFINITY L

Electrical

115V

60Hz

1150W

115V

60Hz

1610W

Capacity

8-1 3/4” rings or 2-3” rings

15-1 3/4” rings or
5-1 3/4” rings and 3-3” rings

Overall
Dimensions

10-3/4”W x 13-7/8”D x 18-3/4”H
(27.3cm x 35.2cm x 47.6cm)

14-1/2”W x 14-3/8”D x 18-3/4”H
(36.8cm x 36.5cm x 47.6cm)

Heating
Chamber
Dimensions

5-1/2”W x 5-1/4”D x 5-1/8”H
(14.0cm x 13.3cm x 13.0cm)

9-1/8”W x 5-1/4”D x 5-1/8”H
(23.2cm x 13.3cm x 13.0cm)

INFINITY M AND L

Number of Programs

30

NIGHT TIME
(DELAY START)

0 - 99 hours
Note: This is the time required for the program to be completed

and ready to cast.

HEAT RATE

*

(Stage 1)

a) 1 - 30°F/min. (1 - 17°C/min.)
b) “FULL” Stage heats at the maximum rate attainable.

HEAT RATE

*

(Stages 2, 3, & 4)

a) 1 - 30°F/min. (1 - 17°C/min.)
b) “FULL” Stage heats at the maximum rate attainable.
c) “NO” Stage is not used.
d) “COOL” Stage cools down to the programmed temperature.

Note: If “NO” is selected for a stage, that stage and all subsequent
stages will not be used. The furnace, therefore, can be used for one,
two, three or four stage operation.

TEMPERATURE

a) Stage 1:

150°F - 2012°F (66°C - 1100°C)

b) Stage 2, 3, 4:

100°F - 2012°F (38°C - 1100°C)

HOLD TIME

0 - 4 hours

*

Programmable heat rates. Actual heat rate at high temperatures may be lower depending upon

furnace load and electrical voltage.

3

ENVIRONMENTAL CONDITIONS

- Indoor use
- Altitude up to 2000 m
- Temperature 5°C to 40°C (41°F to 104°F)
- Maximum relative humidity 80% for temperatures up to

31°C (88°F) decreasing linearly to 50% relative

humidity at

40°C (104°F)

- Mains supply voltage fluctuations not to exceed +/- 10% of the nominal voltage
- Pollution Degree 2, Installation Category II