Appendix A: Configuration

Netcool/Proviso Cisco IP Telephony Technology Pack User’s Guide, Version 4.3-W

441

2. Copy technology-specific files from the DataMart server to the DataChannel server.

Technology-specific files are used to associate a UBA technology pack with a specific instance of the UBA.

Note:

While it is possible to install DataMart and DataChannel on the same server, in a typical installation

these modules are installed on separate servers. If this is the case, use ftp to copy the technology-specific files.

Otherwise, if DataMart and DataChannel are on the same server, use the cp command to copy the files to the

appropriate DataChannel directory.

To copy technology-specific files to the DataChannel server, follow these steps:

2-a. Log in to the Netcool/Proviso DataChannel server by entering the username and password that you

specified when installing and configuring a DataChannel. The default username and password are

pvuser

and

PV

, respectively.

2-b. Change your working directory to the

DATA_CHANNEL_HOME/scripts

directory by entering the

following command, replacing

DATA_CHANNEL_HOME

with the DataChannel home directory

(

/opt/datachannel

, by default):

$ cd

DATA_CHANNEL_HOME/scripts

2-c. Using the

ftp

utility in text mode, log into the DataMart server using the appropriate username and

password (

pvuser

and

PV

, by default).

2-d. Using the

cd

sub-command, change your working directory to the

$PVMHOME/APFiles/voip_cisco_ipt/datachannel/scripts/voip_cisco_ipt

directory.

2-e. Using the

get

sub-command, copy the Bulk Adaptor Design Files (

*.js

), scripts (if any), and other

files (if any) from the DataMart server to the DataChannel server.

2-f. (Pre-443 Netcool/Proviso only) Copy the

voip_cisco_ipt_sample_dc.cfg

template file as

follows:

* Using the

cd

sub-command, change your working directory to the

$PVMHOME/APFiles/voip_cisco_ipt/datachannel/conf

directory.

* Using the

get

sub-command, copy the

voip_cisco_ipt_sample_dc.cfg

template file from the

DataMart server to the DataChannel server.

2-g. Exit the

ftp

utility by entering the

bye

sub-command.

2-h. Verify that the technology-specific files now reside in the target directory as follows:

* (Netcool/Proviso 443 and higher) Verify that the Bulk Adaptor Design Files (

*.js

), scripts (if any),

other files (if any) now reside in the

DATA_CHANNEL_HOME/scripts

directory.

* (Pre-443 Netcool/Proviso) Verify that the Bulk Adaptor Design Files (

*.js

), scripts (if any), other

files (if any), and

voip_cisco_ipt_sample_dc.cfg

template file now reside in the

DATA_CHANNEL_HOME/scripts

directory.

3. Activate data collection requests.

During installation of the technology pack, all predefined data collection requests are promoted to the

database and set to inactive (that is,

idle

displays in the

Active

column of the Netcool/Proviso DataMart

Request Editor). You need to activate these predefined data collection requests using the Request Editor.

To set data collection requests to active, follow these steps:

3-a. Change your working directory to

$PVMHOME/bin

(

/opt/datamart/bin

, by default) on the

DataMart server.

3-b. Invoke the DataMart GUI by entering the following command and pressing