IBM NETCOOL 4.3-W User Manual

Page 465

Advertising
background image

Appendix A: Configuration

Netcool/Proviso Cisco IP Telephony Technology Pack User’s Guide, Version 4.3-W

443

The technology pack’s UBA is responsible for retrieving CCM data, using the Data Direct SQL server bridge

to do so. This bridge is part of the UBA installation. No additional software is required.

You need to set up the Data Direct SQL server bridge to get Call Detail Records from each CallManager

Publisher. The complete configuration is done by editing the

$DC_HOME/conf/odbc.ini

file as user

pvuser

.

[ODBC Data Sources]

Your_Data_Source1

=DataDirect 4.20 SQL Server Wire Protocol

Your_Data_Source2

=DataDirect 4.20 SQL Server Wire Protocol

Your_Data_SourceN

=DataDirect 4.20 SQL Server Wire Protocol

[

Your_Data_Source1

]

Driver=PVmsss20.so

Description=DataDirect 4.20 SQL Server Wire Protocol

Address=

xx.xx.xx.xx,1433

AnsiNPW=Yes

Database=CDR

QuoteId=No

[

Your_Data_Source2

]

Driver=PVmsss20.so

Description=DataDirect 4.20 SQL Server Wire Protocol

Address=

xx.xx.xx.xx,1370

AnsiNPW=Yes

Database=CDR

QuoteId=No

[

Your_Data_SourceN

]

Driver=PVmsss20.so

Description=DataDirect 4.20 SQL Server Wire Protocol

Address=

xx.xx.xx.xx,1433

AnsiNPW=Yes

Database=CDR

QuoteId=No

[ODBC]

IANAAppCodePage=4

InstallDir=/opt/datachannel/

Trace=0

TraceDll=/opt/datachannel/lib/odbctrac.so

TraceFile=odbctrace.out

UseCursorLib=0

All fields above which appear in boldface

red

and must be configured according to your CallManager

Publisher environment, as follows:

Field

Description

[ODBC Data
Sources]

One entry per CallManager Publisher.

Note:
The data source name must match the data source name specified in the corresponding
URI (Uniform Resource Identifier) parameter in the dc.cfg file. Each line in this
section should also be associated with a subsection that configures the data source.