15. Ensure that the Bulk input files can be read.

To verify that the UBA application can read the Bulk input files, follow these steps:

15-a. Place a Bulk input file at the source input location.

(443 only) The source input location for Bulk input files is specified using the URI parameter from the

pack’s XSD file, which you can view using the Topology Editor.

(Pre-443 only) The source input location for Bulk input files is specified using the URI parameter from

the template file, which you added to the

dc.cfg

file in a previous step.

Within the configured file retrieval interval (typically, five minutes), the UBA application retrieves the

Bulk input file and copies it to the following directory:

DATA_CHANNEL_HOME

/UBA.<channel>.<collector>/<instance>/do/

where:

The UBA application then processes the Bulk input file according to the instructions in the Bulk Adaptor

Design File.

Note:

The first time that the UBA processes a Bulk input file, it passes a metric to the CME. The CME

rejects this metric as a BAD_METRIC because the metric does not have an associated grouped sub-element prior

to the time this metric is recorded. This is expected behavior. The CME accepts metrics from the Bulk input files

after the inventory is run.

15-b. Ensure that the UBA application can successfully read the Bulk input file you copied into the source

input location by issuing a

tail

utility command similar to the following:

The UBA application connects to the database.

This event causes a message similar to the following to
display:

DB_CONNECT Connecting to <sid> as

<user>

If you see this database connection message without prior
errors, the UBA application has passed the syntax check.

Event Meaning

Variable Meaning

DATA_CHANNEL_HOME

Is /opt/datachannel

, by default.

<channel>

Specifies the channel number (for example, 1) you
specified when configuring this DataChannel.

<collector>

Specifies the collector number (for example, 100) you
specified when configuring this UBA Bulk Collector.

<instance> (443 only)

Specifies the string for the INSTANCES parameter in the
pack’s XSD file. Typically, this string represents the name
of the pack and is read-only. You can view the string
specified for INSTANCES using the Topology Editor.

<instance> (pre-443 only)

Specifies the string for the INSTANCES parameter in the
pack’s template file. You were instructed to copy this
parameter to the dc.cfg file in a previous step.