IBM 8317 User Manual

Page 57

Advertising
background image

Diagnostic Error Code

FRU/Action

035-0XX-XXX
RAID interface Failure

1.

RAID signal cable

2.

RAID device

3.

RAID adapter card, if installed

4.

System board

035-195-XXX
RAID interface Test aborted by user

1.

Information

2.

Re-start the test, if necessary

035-196-XXX
RAID interface test halt, error threshold
exceeded

1.

Press F3 to review the log file

2.

Re-start the test to reset the log file

035-197-XXX
RAID interface test warning

1.

Make sure the component that is called
out is connected and/or enabled

2.

Re-run test

3.

Component that is called out in warning
statement

4.

Component under test

035-198-XXX
RAID interface test aborted

1.

If a component is called out, make sure
it is connected and/or enabled

2.

Flash the system and re-test

3.

Go to the

″Undetermined problems″

section

035-199-XXX
RAID interface test failed, cause unknown

1.

Go to the

Undetermined problems

section

2.

Flash the system and re-test

3.

Replace component under function test

071-000-XXX
Audio port Interface Test Passed

1.

No action

071-00X-XXX
071-01X-XXX
071-02X-XXX
Audio port error

1.

Run Setup

2.

Flash the system

3.

System board

071-03X-XXX
Audio port failure

1.

Speakers

2.

Microphone

3.

Audio card, if installed

4.

System board

071-04X-XXX
Audio port failure

1.

Run Setup

2.

Audio card, if installed

3.

System board

071-195-XXX
Audio port Test aborted by user

1.

Information

2.

Re-start the test, if necessary

071-196-XXX
Audio port test halt, error threshold
exceeded

1.

Press F3 to review the log file

2.

Re-start the test to reset the log file

Chapter 7. Symptom-to-FRU Index

51

Advertising
This manual is related to the following products: