background image

Diagnostic Error Code

FRU/Action

175-197-XXX
Thermal Sensor(s) test warning

1.

Make sure the component that is called
out is connected and/or enabled

2.

Re-run test

3.

Component that is called out in warning
statement

4.

Component under test

175-198-XXX
Thermal Sensor(s) test aborted

1.

If a component is called out, make sure
it is connected and/or enabled

2.

Flash the system and re-test

3.

Go to

″Undetermined problems″ section

175-199-XXX
Thermal Sensor(s) test failed, cause
unknown

1.

Go to the

Undetermined problems

section

2.

Flash the system and re-test

3.

Replace component under function test

175-250-XXX
175-251-XXX
Thermal Sensor(s) limit error

1.

Check fans

2.

Check Power supply

3.

Microprocessor

4.

System board

185-000-XXX
Asset Security Test Passed

1.

No action

185-XXX-XXX
Asset Security failure

1.

Flash system

2.

System board

185-278-XXX
Asset Security Chassis Intrusion

1.

Assure Asset Security Enabled

2.

C2 Cover Switch

3.

System board

201-000-XXX
System Memory Test Passed

1.

No action

201-XXX-XXX
System Memory error

1.

Replace the memory module called out
by the test

2.

System board

202-000-XXX
System Cache Test Passed

1.

No action

202-XXX-XXX
System Cache error

1.

Cache, if removable

2.

System board

3.

Microprocessor

206-000-XXX
Diskette Drive Test Passed

1.

No action

206-XXX-XXX
Diskette Drive error

1.

Diskette Drive Cable

2.

Check power supply voltages

3.

Diskette drive

4.

System board

215-000-XXX
CD-ROM Drive Test Passed

1.

No action

Chapter 7. Symptom-to-FRU Index

55

Advertising
This manual is related to the following products: