IBM 8317 User Manual

Page 71

Advertising
background image

POST Error Code

FRU/Action

1207

1.

Communications Cable

2.

Dual Async Adapter/A

13XX

1.

Game Adapter

1402
Printer not ready

Information only

1403
No paper error, or interrupt failure

Information only

1404
System board timeout failure

1.

Run Enhanced Diagnostics

1405
Parallel adapter error

1.

Run Enhanced Diagnostics

1406
Presence test error

1.

Run Enhanced Diagnostics

14XX
Not listed above. Check printer before
replacing system board

1.

Printer

2.

System Board

15XX

1.

SDLC Adapter

1692
Boot sequence error

1.

Run FDISK to ensure at least one active
partition is set active

16XX

1.

36/38 Workstation Adapter

1762
Hard disk drive configuration error

1.

Run Configuration. (See “IBM Setup
Utility program” on page 9.)

1780

(Disk Drive 0)

1781

(Disk Drive 1)

1782

(Disk Drive 2)

1783

(Disk Drive 3)

1.

Hard Disk Drive

2.

System Board

3.

Riser card

4.

Hard Disk Cable

5.

Power Supply

1800

PCI/PnP Error! No Hardware Interrupt

Available

1.

Run Setup and verify PCI/ISA
configuration settings.

2.

If necessary, set ISA adapters to Not
available
to allow PCI adapters to
properly configure.

3.

Remove any suspect ISA adapters.

4.

Rerun diagnostics.

5.

PCI Adapter

1801

PCI/PnP Error! No Space Available to

Shadow ROM

1.

Run Setup and verify PCI/ISA
configuration settings.

2.

If necessary, set ISA adapters to Not
available
to allow PCI adapters to
properly configure.

3.

Remove any suspect ISA adapters.

4.

Rerun diagnostics.

5.

PCI Adapter

Chapter 7. Symptom-to-FRU Index

65

Advertising
This manual is related to the following products: