background image

POST Error Code

FRU/Action

111
I/O channel parity error

1.

Reseat adapters

2.

Any adapter

3.

Riser card

4.

System Board

114
Adapter ROM error

1.

Adapter Memory

2.

System Board

3.

Riser card

129
Internal cache test error

1.

Processor

2.

L2 Cache Memory

3.

System Board

135

Fan failure

1.

Fan

2.

System board

151
System board failure

1.

System Board

161
Bad CMOS battery

1.

Run Setup

2.

CMOS Backup Battery (see “Safety
information” on page 109)

3.

System Board

162
Configuration mismatch

1.

Run Setup and verify Configuration

2.

Had a device been added, removed,
changed location? If not, suspect that
device.

3.

Power-on external devices first, then
power-on computer

4.

CMOS Backup Battery (see “Safety
information” on page 109)
System Board

5.

System Board

163
Date and Time Incorrect

1.

Time and Date Set

2.

CMOS Backup Battery (see “Safety
information” on page 109)

3.

System Board

164
Memory Size Error

1.

Run Setup. Check System Summary
menu for memory size change. (See
“IBM Setup Utility program” on
page 9.)

2.

Run the Extended Memory Diagnostic
tests

166
Boot Block Check Sum Error

1.

Run Flash Recovery using Boot Block.
See “Flash recovery boot block jumper”
on page 105.

2.

System Board

167
No Processor BIOS Update Found

1.

Run Setup. Check Stepping level for
the BIOS level needed, then perform
the flash update.

2.

Processor

Chapter 7. Symptom-to-FRU Index