IBM 8317 User Manual

Page 58

Advertising
background image

Diagnostic Error Code

FRU/Action

071-197-XXX
Audio port test warning

1.

Make sure the component that is called
out is connected and/or enabled

2.

Re-run test

3.

Component that is called out in warning
statement

4.

Component under test

071-198-XXX
Audio port test aborted

1.

If a component is called out, make sure
it is connected and/or enabled

2.

Flash the system and re-test

3.

Go to the

″Undetermined problems″

section

071-199-XXX
Audio port test failed, cause unknown

1.

Go to the

Undetermined problems

section

2.

Flash the system and re-test

3.

Replace component under function test

071-25X-XXX
Audio port failure

1.

Speakers

2.

Audio card, if installed

3.

System board

080-000-XXX
Game Port interface Test Passed

1.

No action

080-XXX-XXX
Game Port interface Error

1.

Remove the game port device and
re-test the system

080-195-XXX
Game Port interface Test aborted by user

1.

Information

2.

Re-start the test, if necessary

080-196-XXX
Game Port interface test halt, error threshold
exceeded

1.

Press F3 to review the log file

2.

Re-start the test to reset the log file

080-197-XXX
Game Port interface test warning

1.

Make sure the component that is called
out is connected and/or enabled

2.

Re-run test

3.

Component that is called out in warning
statement

4.

Component under test

080-198-XXX
Game Port interface test aborted

1.

If a component is called out, make sure
it is connected and/or enabled

2.

Flash the system and re-test

3.

Go to the

″Undetermined problems″

section

080-199-XXX
Game Port interface test failed, cause
unknown

1.

Go to the

Undetermined problems

section

2.

Flash the system and re-test

3.

Replace component under function test

086-000-XXX
Mouse Port interface Test Passed

1.

No action

086-001-XXX
Mouse Port interface Presence

1.

Mouse

2.

System board

52

Hardware Maintenance Manual

Advertising