PROCEDURE 11

BATTERIES

B
A

T
T

E

R

I

E
S

1/4-20 x 7/8-Inch

Hex Flange Screw

FIGURE 3 - CONNECTING BATTERY CABLES - DIRECT MOUNT METHOD

Orange Battery

Terminal Cap

POSITIVE

(+) Battery

Terminal/

Post

U-1

Battery

Gray

Battery

Terminal

Cap

Tie-

Wrap

NEGATIVE

(-) Battery

Terminal/

Post

Tie-

Wrap

1/4-20

Hex

Flange

Locknut

Negative (-)

Battery Terminal/

Post

1/4-20 x 7/8-Inch

Hex Flange Screw

Positive (+) Battery

Terminal/Post

U1

Battery

1/4-20 x 7/8-Inch

Hex Flange Screw

NEGATIVE (-) Battery

Terminal/Post

Group 22NF

Battery

POSITIVE (+) Battery Terminal/Post

POSITIVE (+) Red

Battery Cable

NEGATIVE (-)

Black Battery

Cable

DETAIL “B”

1/4-20

Hex

Flange

Locknut

CONNECT BATTERY

CABLE TO BATTERY

TERMINAL AS SHOWN.

DUAL U1 BATTERIES

BLACK BatteryTerminal

Cap

POSITIVE

(+) Battery

Terminal/

Post

Group 22 NF

Battery

RED

Battery

Terminal

Cap

Tie-

Wrap

NEGATIVE

(-) Battery

Terminal/

Post

Tie-

Wrap

DETAIL “A”

DUAL GROUP 22 NF BATTERIES

CONNECT

BATTERY

CABLE(S) RING

TERMINAL(S) TO

THIS SIDE OF

BATTERY

TERMINAL(S)/

POST(S)

DUAL U1 BATTERIES

DUAL GROUP 22 NF BATTERIES