1701

Hard disk(s) diagnostics fail

1. Determine if the hard disk is defined

correctly in BIOS Setup.

2. Check the hard disk drive cable/

connection.

3. Check the hard disk drive.

1762

Primary master IDE has
changed
Primary slave IDE has
changed
Secondary master IDE has
changed
Secondary slave IDE has
changed

1. Make sure the System Boot Drive

parameter in the Startup Options of
BIOS Setup is not set to (Drive A only).

2. Load the default settings in Setup.
3. Insert a system diskette into the

diskette drive and reboot the system.

4. Ensure the diskette drive configuration

setting in BIOS Setup is correct.

5. Check the power to the hard disk drive.
6. Check the Diskette Drive.

1780

Primary master hard disk fail

1. Load the default settings in Setup.
2. Check the IDE drive jumper.
3. Check the power to the IDE drive.
4. Check the IDE cable/connection.
5. Check the IDE drive.

1781

Primary slave hard disk fail

1. Load the default settings in Setup.
2. Check the IDE drive jumper.
3. Check the power to the IDE drive.
4. Check the IDE cable/connection.
5. Check the IDE drive.

1782

Secondary master hard disk
fail

1. Load the default settings in Setup.
2. Check the IDE drive jumper.
3. Check the power to the IDE drive.
4. Check the IDE cable/connection.
5. Check the IDE drive.

Table 4: Error codes and messages (Continued)

Error codes

Error messages

Corrective actions

Note: If any of the errors persist after performing the listed corrective actions, see “Chapter