GENERAL INFORMATION / HIGH PRESSURE DIAPHRAGM PUMP

EXCESSIVE INLET AIR PRESSURE

STATIC SPARK

EXPLOSION HAZARD

HAZARDOUS MATERIALS

HAZARDOUS PRESSURE

INJECTION HAZARD

WARNING

EXCESSIVE AIR PRESSURE. Can cause perĆ

sonal injury, pump damage or property damage.

D

Do not exceed the maximum inlet air pressure as stated on the

pump model plate.

D

Be sure material hoses and other components are able to

withstand fluid pressures developed by this pump. Check all

hoses for damage or wear. Be certain dispensing device is

clean and in proper working condition.

WARNING

STATIC SPARK. Can cause explosion resulting

in severe injury or death. Ground pump and pumping system.

D

Sparks can ignite flammable material and vapors.

D

The pumping system and object being sprayed must be

grounded when it is pumping, flushing, recirculating or

spraying flammable materials such as paints, solvents, lacĆ

quers, etc. or used in a location where surrounding atmoĆ

sphere is conducive to spontaneous combustion. Ground the

dispensing valve or device, containers, hoses and any object

to which material is being pumped.

D

Use the pump grounding lug provided on metallic pumps for

connection of a ground wire to a good earth ground source.

Use Aro Part No. 66885Ć1 Ground Kit or a suitable Ground wire

(12 ga. / 2.6 mm Dia.)

D

Secure pump, connections and all contact points to avoid

vibration and generation of contact or static spark.

D

Consult local building codes and electrical codes for specific

grounding requirements.

D

After grounding, periodically verify continuity of electrical

path to ground. Test with an ohmmeter from each component

(e.g., hoses, pump, clamps, container, spray gun, etc.) to

ground to insure continuity. Ohmmeter should show 100

ohms or less.

D

Submerse the outlet hose end, dispensing valve or device in

the material being dispensed if possible. (Avoid free streamĆ

ing of material being dispensed.)

D

Use hoses incorporating a static wire.

D

Use proper ventilation.

D

Keep inflammables away from heat, open flames and sparks.

D

Keep containers closed when not in use.

WARNING

HAZARDOUS PRESSURE. Can result in serious

injury or property damage. Do not service or clean pump,

hoses or dispensing valve while the system is pressurized.

D

Disconnect air supply line and relieve pressure from the sysĆ

tem by opening dispensing valve or device and / or carefully

and slowly loosening and removing outlet hose or piping

from pump.

WARNING

INJECTION HAZARD. Any material injected into

flesh can cause severe injury or death. If an injection occurs

immediately contact a doctor.

D

Do not grab front end of dispensing device.

D

Do not aim dispensing device at anyone or any part of the

body.

WARNING

HAZARDOUS MATERIALS. Can cause serious

injury or property damage. Do not attempt to return a pump to

the factory or service center that contains hazardous material.

Safe handling practices must comply with local and national

laws and safety code requirements.

D

Obtain Material Safety Data Sheets on all materials from the

supplier for proper handling instructions.

WARNING

EXPLOSION HAZARD. Models containing aluĆ

minum wetted parts cannot be used with III.ĆTrichloroethane,

Methylene Chloride or other Halogenated Hydrocarbon solĆ

vents which may react and explode.

D

Check pump motor section, fluid caps, manifolds and all

wetted parts to assure compatibility before using with solĆ

vents of this type.

CAUTION

Verify the chemical compatibility of the pump

wetted parts and the substance being pumped, flushed or reĆ

circulated. Chemical compatibility may change with temperaĆ

ture and concentration of the chemical(s) within the

substances being pumped, flushed or circulated. Consult

ARO Form No. 8677ĆP, Fluid Compatibility Guide, for informaĆ

tion on chemical compatibility.

CAUTION

Maximum temperatures are based on mechaniĆ

cal stress only. Certain chemicals will significantly reduce

maximum safe operating temperature. Consult Fluid CompatĆ

ibility Guide for chemical compatibility and temperature limĆ

its.

CAUTION

Be certain all operators of this equipment have

been trained for safe working practices, understand it's limitaĆ

tions, and wear safety goggles / equipment when required.

CAUTION

Do not use the pump for thestructuralsupportof

the piping system. Be certain the system components are

properly supported to prevent stress on the pump parts.

D

Suction and discharge connections should be flexible conĆ

nections (such as hose), not rigid piped, and should be comĆ

patible with the substance being pumped.

CAUTION

Prevent unnecessary damage to the pump. Do

not allow pump to operate when out of material for long periĆ

ods of time.

D

Disconnect air line from pump when system sits idle for long

periods of time.