— Absolute — Compares the values directly with the thresholds at the end of the

sampling interval.

Delta — Subtracts the last sampled value from the current value. The difference

in the values is compared to the threshold.

Rising Threshold — Displays the rising counter value that triggers the rising

threshold alarm. The rising threshold is presented on top of the graph bars. Each

monitored variable is designated a color.

Rising Event — Displays the user-defined description of the event.

Falling Threshold — Displays the falling counter value that triggers the falling

threshold alarm. The falling threshold is graphically presented on top of the graph

bars. Each monitored variable is designated a color.

Falling Event — Displays the user-defined description of the event.

Startup Alarm — Displays the trigger that activates the alarm generation. Rising is

defined by crossing the threshold from a low-value threshold to a higher-value

threshold.

Interval (sec) — Defines the alarm interval time in seconds.

Owner — Displays the device or user that defined the alarm.

2. Click .

The

Add Alarm Entry Page opens:

Figure 114. Add Alarm Entry Page

3. Define the relevant fields.
4. Click

. The entry is added to the Add Alarm Entry Page, and the

device is updated.