Connect the fan cables to the mid-plane, Install the optical drive cable (optional), Replacing a redundant system fan – Intel SERVER SYSTEM SR2500AL User Manual

Page 117

Advertising
background image

Intel® Server System SR2500AL User’s Guide

95

12. Connect the fan cables to the mid-plane.
13. Install the large air baffle. For instructions, see

“Installing the Large Air Baffle”

.

14. Install the bridge board. For instructions, see

Figure 64 “Installing the Bridge

Board into the Server System” on page -73

.

15. Install the optical drive cable (optional).
16. Install the PCI riser assembly. For instructions, see

“Installing the PCI Riser

Assembly”

.

17. Install the processor air duct. For instructions, see

“Installing the Processor Air

Duct”

.

18. Install the server system cover. For instructions, see

“Installing the Server System

Cover”

.

19. Plug all peripheral devices and the AC power cable(s) into the server.

Replacing a Redundant System Fan

Note: The fans that are integrated into the power supply cannot be replaced separately. If one of

the fans in the power supply fails, the power supply must be replaced.

The system fans at the front of the server system can be individually replaced if one of

them fails. Use the steps below to replace a system fan.

1. Observe the safety and ESD precautions at the beginning of this book. See

“Safety

Information”

.

2. Remove the server system cover. For instructions, see

“Removing the System

Cover”

.

3. There are no screws to loosen. Lift the failed fan from the module.