Removing the intel® rmm and intel® rmm nic, Figure 60. removing the intel, Removing the intel – Intel SERVER SYSTEM SR2500AL User Manual

Page 92: Rmm and intel, Rmm nic

Advertising
background image

70

Intel® Server System SR2500AL User’s Guide

Removing the Intel

®

RMM and Intel

®

RMM NIC

1. Observe the safety and ESD precautions at the beginning of this book. See

“Safety

Information”

.

2. Power down the server and unplug all peripheral devices and the AC power

cable(s).

3. Remove the server system cover. For instructions, see

“Removing the System

Cover”

.

4. Remove the PCI riser assembly. For instructions, see

“Removing the PCI Riser

Assembly”

.

5. Remove the Intel

®

RMM board from the server board (see letter “A” in the figure

below).

6. Remove the Intel

®

RMM NIC module from the server board (see letter “B” in the

figure below).

7. Remove the standoffs from the server board (see letter “C” in the figure below).
8. Install the Intel

®

RMM NIC module cover into the system back panel (see letter

“D” in the figure below).

Figure 60. Removing the Intel

®

RMM and the Intel

®

RMM NIC Module from

the Server System

9. Install the PCI riser assembly into the server system. For instructions, see

“Installing the PCI Riser Assembly”

.

10. Install the processor air duct. For instructions, see

“Installing the Processor Air

Duct”

.

11. Install the server system cover. For instructions, see

“Installing the Server System

Cover”

.

12. Plug all peripheral devices and the AC power cable(s) into the server.

AF000744

A

B

D

C

Advertising