Figure 14. removing a fixed fan, Replacing a fixed fan (intel – Intel SC5400 User Manual

Page 41

Advertising
background image

Intel® Server Chassis SC5400 User’s Guide

23

Replacing a Fixed Fan (Intel

®

Server Chassis

SC5400Base SC5400BRP only)

Note: This procedure applies only to the Intel

®

Server Chassis SC5400 BASE and Intel

®

Server

Chassis SC5400BRP configurations. The Intel

®

Server Chassis SC5400LX and

SC5400LXi ship with hot-swap fans.

1. Observe the safety and ESD precautions at the beginning of this book.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the chassis cover. For instructions, see

“Removing the Chassis Cover” on

page 16

.

4. Disconnect the appropriate fan power cable from the server board.
5. Remove the 92-mm (see letter “A” in the following figure) or 120-mm (see letter

“B”) fixed fan from its snap-in bracket.

Figure 14. Removing a Fixed Fan

6. Install new 92-mm or 120-mm fixed fan.
7. Connect fan power cable to the server board. See the Intel

®

server board Quick

Start User’s Guide or User Guide for appropriate connection location.

8. Re-install the chassis cover. For instructions, see

“Installing the Chassis Cover” on

page 17

.

9. Plug all peripheral devices and the AC power cable into the server and then power

up the server.

TP00991

B

A

120-mm
Fixed Fan

92-mm

Fixed Fan

Advertising