CV-M40

TRIG

XSUB

Enlarged

Note : The following charts discribes the delay of the exposure

Exposure time

1.4 ~ 1.5 sec.

Note 1:Sync or HD is not mentioned

Note 2:1H=31.777 S

Note 3:WEN polarity can be chosen at JP22 of I/F board

0.032mS 40mS

Ext.Trig

VIDEO OUT

WEN(positive)

WEN(Negative)

Valid period

Waiting for

Ext.Trigger

Exposure time

3-c) partial scan

A

B

C

7H

1H

Effective readout line

A

B

C

240 line

45H

240H

13H

120 line

66H

120H

17H

60 line

80H

60H

19H

30 line

87H

30H

20H