Cv-m40, 2. jumpers on board – JAI CV-M40 User Manual

Page 17

Advertising
background image

CV-M40

17

7-2. Jumpers on board

7-2-2. Jumpers on PK8202 board

Jumpers JP5, JP6 and JP7 enable or disable the ext. trigger input, the WEN output and pixel

clock output, respectively.

7-2-1. Jumpers on PK8201 board

Jumpers JP1 and JP2 are used to select the gamma setting. See table below for options.
Please note that both jumpers must be in the “open” position to allow RS 232C setting of
gamma. If no setting is provided via RS 232C, the camera will default to gamma 1.0.

Do not set the jumpers both JP1/JP2 at short circuited, as it causes a serious damge to the camera.

Note : Gamma is set at “Setting by RS 232C interface” with 1.0.

Jumpers

Setting by jumpers

Setting

by

RS 232C

Forbidden

0.45

1.0

JP1

Short

Open

Open

Short

JP2

Open

Short

Open

Short

JP1

JP2

#5 of 6pin connector

#6 of 6pin connector

#9 of 12 pin connector

NC

Open

Trigger in

Short

NC

Open

WEN out

Short

Jumpers

JP5
JP6
JP7

NC

Open

Pixel clock out

Short

H Reset Trigger Mode and H Non Reset Trigger Mode are corresponding

to the following triggers: Edge Pre-select Mode, Pulse Width Control

Mode, and Frame Delay Readout Mode

(12P):Trigger Mode using only 12 pin connector

(6P): Trigger Mode where 6 pin connector is used for both Trigger and

WEN, and 12 pin connector is used for HD input.

JP7 and JP18 must not be SHORT at the same time.

Function Mode

Rear Board (PK8202)

JP5 JP6 JP7 JP18 JP19 JP20 JP21

Int. Sync

O

O O/S O/S O/S O O/S

Ext. Sync

O

O O/S O/S S

O

S

H Rest Trigger (12P)

O

O O/S O/S S

O

S

H Non Reset Trigger (12P) O

O O/S O/S S

O

S

H Rest Trigger (6P)

S

S O/S O/S O

O

O

H Non Reset Trigger (6P)

O

S O/S O/S O

S

S

O=Open S=Short

JP19

JP21

JP20 JP5

JP18

JP6

JP7

CAUTION

Advertising