CV-M40

13

4.Pulse width control mode

Note 1:Sync or HD is not mentioned

Note 2:1H=31.777 S

Note 3:WEN polarity can be chosen at JP22 of I/F board

Waiting for Ext.Trigger

Waiting for Ext.Trigger

Valid period

Valid period

Ext.Trig

VIDEO OUT

WEN(positive)

WEN(Negative)

Ext.Trig

VIDEO OUT

WEN(positive)

WEN(Negative)

0.064mS 40mS

0.064mS 40mS

494H

Exposure time

Exposure time

1H

8H

1H

7H

1H

1H

1H

7H

7H

14H

4-b) 120 fps = binning readout

4-a) 60 fps = normal readout

not re-set at HD sync

not re-set at HD sync

247H

Ext.Trig

VIDEO OUT

WEN(positive)

WEN(Negative)

4-c) Partial scan

0.064mS 40mS

Exposure time

Valid period

Waiting for

Ext.Trigger

7H

1H

1H

A

B

C

Effective readout line

A

B

C

240 line

45H

240H

13H

120 line

66H

120H

17H

60 line

80H

60H

19H

30 line

87H

30H

20H

Note 1:Sync or HD is not mentioned

Note 2:1H=31.777 S

Note 3:WEN polarity can be chosen at JP22 of I/F board