c) JP22 WEN Polarity Reversing

When JP22 is set to OPEN, WEN is output, and only 1H period becomes HIGH level before

video output starts. The periods from WEN output and video start may differ at each mode.

When JP22 is set to SHORT, WEN’s image output period becomes LOW level, and after finish-

ing output, it becomes HIGH level.

The periods from WEN output and video start is same at each mode.