Removing a Battery from an EX8208 Switch for Recycling

The EX8208 switch contains a CR2032 2.7-volt lithium battery on each Switch Fabric
and Routing Engine (SRE) module installed in the chassis. The coin-shaped battery is
approximately 0.75in. (20 mm) in diameter. The battery is estimated to last for over 50
years.

A base configuration switch has one SRE module, and a redundant configuration switch
has two modules installed. Before recycling an SRE module or the switch chassis, remove
the battery from each SRE module for battery recycling.

Before you begin to remove the battery:

Power off the switch or take the SRE module offline. If only one SRE module is installed
in a powered-on switch, you must halt the module before removing it. See “Taking the
SRE Module Offline in an EX8208 Switch” on page 213.

Ensure that you have the following parts and tools available:

Phillips (+) screwdriver, number 2

Electrostatic discharge (ESD) grounding strap

To remove the battery from an SRE module in the switch (see Figure 95 on page 234):

1.

Attach the antistatic discharge (ESD) grounding strap to your bare wrist, and connect
the strap to one of the ESD points on the chassis.

2.

Locate the SRE module in the switch chassis.

3.

With the screwdriver, loosen the captive screws on each side of the SRE module by
turning them counterclockwise until they are completely unseated.

4.

Pull both ejector levers outwards, away from the faceplate of the SRE module, until
they go no further. This action causes the module to slide slightly out of the chassis.

5.

Grasp the ejector levers, and pull the SRE module out to about halfway.

6.

Place one hand underneath the module to support it, and slide it completely out of
the chassis.

7.

Locate the coin-shaped CR2032 battery on the right side of the module near the
third post (see Figure 95 on page 234).

8.

With your finger, pry the battery out of its socket.

9.

If you are recycling the entire chassis of a redundant configuration, repeat Steps 2
through 8 for the second SRE module.

10.

Recycle the battery or batteries as required.