N+1 redundancy configuration of ac power supplies, Configurations using 2000 w ac power supplies – Juniper Networks EX8208 User Manual

Page 68

Advertising
background image

is 52 VDC. The output power is 1200 W for low-voltage line input and 2000 W for
high-voltage line input.

The 3000 W AC power supply supports only the high-voltage line input (200–240 VAC)
AC power configuration. Low-voltage line input is not supported for the 3000 W AC
power supplies on the EX8200 switches. The output is 52 VDC. The output power is
3000 W for high-voltage line input.

N+1 Redundancy Configuration of AC Power Supplies

N+1 redundancy configuration is required for normal operation of EX8200 switches. In
an N+1 redundancy configuration, if one power supply fails or is removed, the remaining
power supplies continue to supply power for the switch without interruption.

Depending on the configuration type of the switch and the input voltage, determine the
number of power supplies needed (N) for a switch. Install an additional power supply to
meet the required N+1 redundancy configuration. For details about different switch
configurations, see “EX8208 Switch Configurations” on page 6 or EX8216 Switch
Configurations.

The tables in this section list the N+1 power requirements for different EX8200 switch
configurations:

Table 17 on page 42—Lists the N+1 power requirements of EX8208 switch configurations
that use 2000 W AC power supplies.

Table 18 on page 43—Lists the N+1 power requirements of EX8208 switch configurations
that use 3000 W AC power supplies.

Table 19 on page 43—Lists the N+1 power requirements of EX8216 switch configurations
that use 2000 W AC power supplies.

Table 20 on page 43—Lists the N+1 power requirements of EX8216 switch configurations
that use 3000 W AC power supplies.

Table 17: N+1 Power Redundancy Configurations for Different EX8208
Switch Configurations Using 2000 W AC Power Supplies

Power Supplies
Needed for N+1

Power Supplies
Needed (N)

Input Voltage

Switch
Configuration

2

1

High-voltage line
(200–240 VAC)

Base

3

2

Low-voltage line
(100–120 VAC)

4

3

High-voltage line
(200–240 VAC)

Fully loaded with
8-port SFP+ line
cards

6

5

Low-voltage line
(100–120 VAC)

Copyright © 2010, Juniper Networks, Inc.