Factory preset of mode settings, System resetting method – JVC RK-LP55U User Manual

Page 20

Advertising
background image

E-20

FACTORY PRESET OF MODE SETTINGS

The default values (factory preset) for each of the RM-LP55’s modes are shown below.

Any setting data which is currently displayed on the LCD can be reset to the default value (shown in
the table above) by pressing the FUNC1

and

buttons

C or the FUNC2

and

buttons

D

simultaneously.
You can also simultaneously reset all settings to the default values as described in the next section.

System resetting method

While pressing the MENU

and

buttons

B

simultaneously, set the OPERATE switch to
ON.

ASYSTEM RESETB appears on the display,
then the unit returns to its normal operating
state.

System resetting does not affect scene files
(A and B) or current camera settings.

AUTO IRIS LEVEL, ALC IRIS SET and
CAMERA TYPE settings cannot be reset by
the system resetting, (

AREMOTE

CONTROLLER OPERATION MODE
SETTINGS

B (A pg. 18)).

Mode

Factory preset

Mode

Factory preset

CAM MODE

CAM

RANDOM TRIGGER

OFF

CONTOUR

ON

HI-RESO

OFF

CONTOUR LEVEL

0

SHUTTER

NORMAL

SC COARSE

V.SCAN

1/60.0 (U-ver.)

SC FINE

0

1/50.0 (E-ver.)

H.PHASE

0

SLOW

1 FRM

GAMMA

ON

GAIN MODE

0 dB

IRIS DETECT

NORMAL

WHITE BALANCE

AUTO1

TITLE

OFF

PAINT

OFF

TITLE POSITION

1

-

-

SYSTEM RESET

MENU

While pressing these

simultaneously, set

OPERATE to ON.

RM-LP55_U_E.book Page 20 Monday, July 25, 2005 2:57 PM

Advertising