SATO CL408e User Manual

Page 59

Advertising
background image

SERVICE MODE

The Service mode is exited by powering the printer off and
then back on.

COUNTER MODE

The Counter Mode is provided to allow the user to access the internal printer
cousters.

ADVANCED MODE

The Counter Mode is accessed from the Advanced Mode.
Press the LINE key to step to the Counter Mode.

COUNTER MODE

Pressing the FEED key will advance the display to the counter
selections.

SELECT COUNTER

HD DSP CUT LIFE

The counters are identified in the display as:

HD:Head Counter (should be reset when print head is
replaced)
DSP: Dispense Counter
CUT: Cutter Counter
LIFE: Life Counter (cannot be reset)

1.

Use the LINE key to step the cursor to the desired
counter, the Head (HD) counter or the LIFE counter. The
default position is the Head Counter. Use the LINE key to
advance the cursor to the desired selection.

HEAD COUNTER

XXXXX M

2.

Pressing the FEED key again will advance the counter to
the Clear mode. All counters with the exception of the
LIFE counter may be cleared.

3.

Once the correct setting is highlighted, pressing the FEED
key will display the current value (in meters)stored in the
counter.

HD CNTR CLEAR

YES

NO

4.

Use the LINE key to select the desired setting. If you only
wanted to read the counter value, select NO. If you want
to read the counter and reset it to 0.0, place the cursor
over the YES. Once the desired setting is selected,
pressing the FEED key will advance the return you to the
Counters Mode display.

COUNTERS MODE

5. To exit the Counters Mode, turn power to the printer off and

then back on.

TEST PRINT MODE

The Test Print Mode offers four different printer status labels for troubleshooting. If
DSW3-5 is OFF, the Test Print cycle must be initiated with a Print Start command.

Page 3-22