nTier700 BlueScale Firmware

Firmware Package History

July 2012

Release NotesSpectra nTier700 Backup and Archive Appliance

17

Known Issues

BlueScale2.6.0.7

This release improves the overall reliability of the nTier700.

Resolved Issues

The File Migrator installation files have been added to system disk on the 
the 64‐bit Windows version of the nTier700. 

Note:

As of BlueScale2.7.1.7, File Migrator is no longer included with 
the nTier700.

Problem

Workaround

The Driver Install/Update wizard in Windows 
Device Manager does not correctly install tape 
drive device drivers on the nTier700.

Follow the instructions in “Updating Tape Drive 
Device Drivers” section of the Spectra nTier700 
Backup and Archive Appliance User Guide
 to 
download the appropriate drivers and install 
them.

Note:

If you previously installed/updated the 

device drivers using the wizard, you must first 
uninstall the drivers and devices, then reinstall 
them.

The device drivers for IBM LTO‐4 tape drives 
included in the BlueScale2.7.1.7 firmware 
package does not support half‐height IBM LTO‐4 
tape drives. 

Download and install the most current LTO‐4 
device drivers. Refer to “Updating Tape Drive 
Device Drivers” section of the Spectra nTier700 
Backup and Archive Appliance User Guide
 for 
instructions.

When sending ASL files generated by 
AutoSupport, the send log operation fails if the 
E-mail From field in the AutoSupport Mail 
Recipients configuration contains an “@” symbol. 

When configuring mail recipients in 
AutoSupport, leave the E-mail From field empty 
or simply include the domain (for example, 
spectralogic.com).

If the Windows password is left blank, you 
cannot login into BlueScale from either a direct 
connection to the Windows operating system or 
through the BlueScale web interface. 

Make sure that you set the Windows password. 
Do not leave it blank. Refer to the Spectra nTier700 
Backup and Archive Appliance User Guide
 for 
information about setting the Windows 
Administrator password.

The BlueScale web interface may not operate 
correctly when accessed by a server running 
Windows Server 2008 AND Internet Explorer 7. 

Use Mozilla Firefox or a different version of 
Internet Explorer. 

When multiple servers are connected to the 
nTier700 and actively transferring data, you 
occasionally lose access to shared folders when 
the BlueScale web interface is running. 

If you have a large number of clients attached to 
the system and lose access to shared folders, 
configure the system to restart the Server service 
automatically.