Firmware Package History

July 2012

Release NotesSpectra nTier700 Backup and Archive Appliance

21

When installing the nTier700, make sure that it 
can access a properly configured DHCP/DNS 
server. Or, enter a known good IP address if you 
are using a static IP address. Otherwise, Remote 
Desktop may not work. If it doesn’t, attach a 
monitor, keyboard and mouse to the nTier700 so 
you can review the event log. Look for the 
following error, which corresponds to the Remote 
Desktop connection attempt:
The RDP protocol component “DATA 
ENCRYPTION” detected an error in the protocol 
stream and has disconnected the client.

Event Type: Error
Event Source: TermDD
Event ID: 50
Description:

If you see this error, follow the directions found 
in Microsoft’s KnowledgeBase article KB323497 

http://support.microsoft.com/kb/323497

 

to repair 

the problem.

At the end of a package update, you may not be 
automatically redirected to the BlueScale Web 
interface login page. 

If the upgrade seems to have stalled after 
rebooting, manually connect to the login page.

If one or more drives assigned to a logical volume 
have failed or are missing, there is no information 
about the drives on Logical Volumes page of the 
BlueScale web interface.

Check the Drives tab on the blade’s operator 
panel or the Overview screen on the web 
interface to identify the missing drives.

If Microsoft System Center Data Protection 
Manager (DPM) 2007 writes to tape do not 
succeed, check the drive mapping. The drives 
must be associated with a library—for example, 
refer to the following screen, which shows 
correctly mapped drives. This is a known 
Microsoft bug, and Spectra Logic is waiting for 
the patch to fix this problem.

Note:

As of BlueScale2.7.1.7 DPM is no longer 

included with the nTier700.

If the drives are not mapped correctly: 
1.

Stop DPM.

2.

Start the Microsoft Removable Storage 
Manager (RSM) service and map the tape 
drives.

3.

Stop the RSM service.

4.

Restart DPM. The drives should be mapped 
correctly and writes should now succeed.

Problem