Firmware Package History

July 2012

Release NotesSpectra nTier700 Backup and Archive Appliance

22

If you are using a tape library with IBM LTO tape 
drives in conjunction with your nTier, the 
standard Windows device driver installation (via 
the Add New Hardware wizard) does not install 
all the software needed to take advantage of the 
tape drives’ features. 

If the system automatically assigned drivers to 
the tape drives, uninstall the device drivers for 
the tape drives after you install the unit. Then, 
use the following procedure to install the correct 
device drivers:
1.

Open a command prompt window (Start >
Accessories > Command Prompt
).

2.

Type the following command to switch to the 
directory where the LTO tape device drivers 
are located:
cd C:\Program Files (x86)

\SpectraLogic\drivers\IBM LTO Tape

Drives 6.1.7.8

Note:

The number included in the IBM LTO 

Tapes 6.1.7.8 sub‐directory name may not be 
same as in this step (for instance, IBM LTO Tapes 
6.1.7.9 instead of IBM LTO Tapes 6.1.7.8).
3.

Type 

install

 if you are not using Microsoft 

Data Protection Manager (DPM) or Microsoft 
Removable Storage Manager (RSM). 
– or – 
Type 

install -n

 if you are using DPM or 

RSM.

When entering information through the 
BlueScale web interface, using the keyboard Enter 
key may not work as expected.

Use the buttons in the interface instead of the 
keyboard. For example, after entering the folder 
information, click the OK button on the user 
interface instead of pressing the Enter key to 
create the folder.

After power‐cycling the nTier700, you may 
experience a problem connecting to the BlueScale 
Web interface through Ethernet port 1 even 
though the unit is functioning normally (that is, 
the IP information for Ethernet port 1 is correct 
and unchanged, the BlueScale service is running, 
and the BlueScale login screen is available 
locally). 

One workaround is to power‐cycle the nTier700 
again. The other workaround is to log into the 
nTier700 locally and then disable and enable the 
network interface card through the Windows 
interface.

If you leave the focus of your Web browser on the 
Blades page for a long period of time, a memory 
leak may occur. When this happens, the browser 
and the Windows operating system begin to lag, 
with functions like opening the Start menu taking 
much longer than normal.

To recover the memory, close your browser 
session.

Problem

Workaround

Advertising