Firmware Package History

July 2012

Release NotesSpectra nTier700 Backup and Archive Appliance

19

If you are updating the firmware for the root 
expanders from a previous version, the firmware 
update fails if there is I/O to the drives during the 
update.

Before you update the nTier700 firmware for the 
root expanders, stop all I/O to the drives, then 
stop BlueScale. The expander firmware is 
updated as part of the BlueScale2.2 or 2.3 to 
BlueScale2.6.0.6 update procedure performed by 
Spectra Logic Technical Support.

Occasionally, you may not be able to navigate to 
the BlueScale Network screen when the optional 
10 GigE NIC is installed.

1.

Access the Windows desktop.

2.

Configure the IP addressing for the installed 
network interface cards through Windows. 
Select Start > Settings > Network
Connections
, select the desired connection, and 
then click Properties to configure the IP 
addressing.

BlueScale posts critical error messages about 
missing blades immediately following a system 
start or reboot. 

Ignore critical messages concerning the missing 
blades IF they are posted immediately following 
a BlueScale restart (for example, a system reboot).
Mark the messages as Read and then continue to 
monitor the messages for subsequent critical 
alerts for the same components.

If you have a proxy server defined for Internet 
Explorer you cannot use the Download From
Spectra
 option to update the nTier700 BlueScale 
firmware. 

Download the firmware update file to either a 
USB drive or a firmware package server and 
update the firmware from there.

Occasionally you may receive an internal server 
error when changing IP settings for Ethernet 
port 2 through BlueScale. 

Restart the browser you are using to access the 
BlueScale web interface and reconnect to the 
nTier700.

The BlueScale login page does not display 
following a firmware update. Instead the status 
page that the system is restarting remains. 

Refresh the BlueScale web interface by pressing 
function key 5 (F5) on your keyboard.

File Migrator. The nTier File Migrator installation 
file is not currently stored on the nTier700 
integrated application server system disk. 

Notes:

 This issue is resolved in BlueScale2.6.07.
 As of BlueScale2.7.1.7 File Migrator is no longer 

included with the nTier700.

Contact SpectraGuard Technical Support for 
assistance (see 

Contacting Spectra Logic on 

page 4

).

File Migrator. The License Administration Utility 
and Activating without Internet Access process 
described in the nTier File Migrator User Guide 
does not work. 

Note:

As of BlueScale2.7.1.7 File Migrator is no 

longer included with the nTier700.

Connect the nTier appliance to a network that has 
internet connectivity and select Internet as the 
activation option. If you do not have web access, 
contact Spectra Logic Technical Support for 
assistance (see 

Contacting Spectra Logic on 

page 4

).

Problem

Workaround

Advertising