RECORDING CONDITIONS SET

4

English

57

Settings can be made to indicate whether overwriting is to
be performed (deleting old images) recording is to be
stopped when any of the hard disk’s recording areas
become full. In the latter case, the remaining capacity is
shown as a percentage on the operation display area.

1

Move the cursor to “OVERWRITE”
under “NORMAL RECORDING AREA”
and press the [ ] button, then press the
[

] or [

] button to select “OFF”.

“**” from “REMAINING DISK WARNING” changes to “1%”.

[Settings] (‹ indicates default setting.)

2

Press the [ ] button.

The cursor moves to “OVERWRITE” for the alarm
recording area.

z

If this setting is turned “OFF”, the space warning or
ALARM FULL indicator will start to flash when the
remaining hard-disk capacity reaches the percentage
set for “REMAINING DISK WARNING”.

3

Press the [ ] button, then press the [

]

or [

] button to select “OFF”.

[Settings] (‹ indicates default setting.)

z

Each menu setting should be performed for each
individual unit.

4

Press the [ ] button to move the cursor
to “REMAINING DISK WARNING” and
press the [ ] button, then press the [

]

or [

] button to select a remaining

capacity value.

(Example: 5%)
The remaining capacity can be set anywhere between 1%
(default) and 10%.

5

Press the [EXIT/OSD] button.

The display returns to the normal screen.
A warning will be displayed in the operation display area
when the remaining capacity for any recording area
reaches setting value. In addition, the ALARM indicator
(for the normal recording area) or the ALARM FULL
indicator (for the alarm recording area) will flash at this
time.

Setting normal recording area
overwriting and remaining capacity
on the operation display area

Setting

Description

OFF

Recording is stopped when the normal recording
area becomes full.

‹

ON

Overwriting automatically starts from the beginning
of the normal recording area when it becomes full.

Setting

Description

OFF

Recording is stopped when the alarm recording
area becomes full.

‹

ON

Overwriting automatically starts from the beginning
of the alarm recording area when it becomes full.

ALARM FULL indicator

FULL indicator

Operation

display area

Remaining

capacity

display

z

5%

10-20-04 ALARM 0000

08:30:00 EN

10FPS

e00_l8had_us_7.book Page 57 Wednesday, March 10, 2004 2:47 PM