Interface specifications, Rs-232c, Rs-485 – Sanyo DSR - 300 User Manual

Page 82

Advertising
background image

English

81

(when optional interface board is installed)

1

INTERFACE SPECIFICATIONS

Data format

Only the data transfer speed can be set. (JP. 69)

Communication protocol

Communication is carried out in units of 1 byte. After the
PC has transmitted a single byte, it waits for a response
from the unit before sending the next byte.
An ON (F6) command is sent as the start command, and
the unit will continue to accept commands until an OFF
(F7) command is sent as the end command. Whenever the
unit receives a command, it returns an ACK (OA).

When using RJ-11 connector

A: Non-inverting driver output, non-inverting receiver input
B: Inverting driver output, inverting receiver input

Communication wire: 2-core wire

Communication system: Half duplex

Data format

To set the data transmission speed, address and
termination switch, see “Settings for RS-232C and RS-
485” (JP. 69).

Communication protocol

A proprietary Sanyo protocol (SSP: Security Serial
Protocol) is used. Use of a Sanyo system controller is
recommended.

RS-232C

Pin No.

Signal

Operation

Signal direction

1

2

RXD

Reception

PC

→ Unit

3

TXD

Transmission

Unit

→ PC

4

5

GND

Ground

6

7

RTS

Transmission

request

Unit

→ PC

8

9

Mode

Asynchronous

Character length

8 bits

Data transmission
speed

2400, 4800, 9600, 19200 bps

Parity check

None

Stop bit

1

9

8

7

6

5

4

3

2

1

RS-485

Pin No.

Connector A signal

Connector B signal

1

Not used

Not used

2

Not used

Not used

3

A

B

4

B

A

5

Not used

Not used

6

Not used

Not used

Mode

Asynchronous

Character length

8 bits

Data transmission
speed

2400, 4800, 9600, 19200 bps

Parity check

None

Start bit

1

Stop bit

1

1

6

e00_l8had_us_7.book Page 81 Wednesday, March 10, 2004 2:47 PM

Advertising