Installation, Trouble shooting – Skylink AM-100 User Manual

Page 11

Advertising
background image

Enter master

3 beeps for valid

password to

password. 1 long

programming mode

beep for invalid
password.

[1] - Master password
[2] - Secondary password
[3] - Duress password

Select any 4-digit pass-
word, each digit can be
from 0 to 9

Enter the new password

3 beeps if new pass-

again for confirmation

word is accepted. You
will hear [Password
Accepted]

Programming Passwords

Master Password

can be used for programming, arming, disarming the

system, and telephone access. The default Master Password is [1234].

Secondary Password

can be used for arming, disarming the system, and

telephone access. Secondary Password cannot be used for programming.
The default Secondary Password is [0000].

Duress Password

is used when you are forcibly compelled to disarm the

control panel. Entering the duress password will stop the siren from sounding
but the control panel will silently call the emergency phone numbers for help.
The default Duress Password is [3838]. You should definitely change this
password and let all the users know this password.

Changing Passwords

It is strongly recommended to change all 3 passwords when you first set
up the system.

In order to change the password, follow the procedures below.

INSTALLATION

[PROG]

[MPIN]

[2]

[1] or
[2] or
[3]

[new
4-digit
password]

[new
4-digit
password]

Enter
Programming
mode

Select
password
programming

Select which
password to
change

Enter new
password

Enter new
password to
confirm

1

2

3

4

5

9

Step

Keys

Function

Description

Note

Questions

Solutions

Why I can’t arm my system?

Make sure none of the sensors are
triggered. You can check this by the zone
LEDs, none of them should blink.

I cannot arm the system even when no

You need to disarm the system again by

sensor is triggered, and the ARM LED

either entering the password or disarm by

is off.

keychain remote. Although the ARM LED
is off, but the system is not completely
disarmed after an alarm was triggered.
Refer to page 19 on how to completely
disarm a control panel after an alarm has
been triggered.

Why the ARM LED keeps flashing?

That means you have not programmed any
emergency phone numb ers. For instructions
on how to program emergency phone
numbers, please see page 10.

How do I exit programming mode

You can press the programming button on

when I’m in the middle of it?

the side of the unit to quit programming
anytime.

When a sensor is triggered, the alarm

You have programmed that sensor in alarm

sounds instantly even it is not armed,

mode, instead of beep mode. Please refer

why is that?

to page 26 for instructions of how to program
it back to beep mode.

When the alarm is triggered, why

The control panel will stop calling when it

the control panel won’t call all the

is disarmed by any one of the recipients.

programmed phone numbers? It

Disarm can also be done locally thru the

always stops before calling the

keypad on the control panel by entering a

last number.

valid password.

Why the control panel doesn’t beep

You have placed the buzzer mode selector

when a sensor is triggered, while

on the side of the control panel to “II”, this

only the zone LED flashes?

will disable the beeping. Placing it to “I” will
enable the beeping.

The control panel is in armed mode,

If the triggered sensor is programmed in the

why activating a sensor will not cause

Alert Zone (Bypass Zone), alarm will not

an alarm, or call any emergency phone

sound, and emergency call will not be made

number?

if this sensor is triggered. The control panel
will only respond when it is disarmed, in
alert mode.

TROUBLE SHOOTING

Control Panel

44