Installation, Home automation – Skylink AM-100 User Manual

Page 14

Advertising
background image

T

M

12

Window / Door Sensor is used to monitor doors or windows that
open and close. When these doors / windows are open or
closed, the sensors will transmit a signal to the control panel to
notify the user. These sensors consist of 2 parts, one is the
transmitter, the other is the magnet.

Before installing the sensor, remove the battery isolator by pulling out the yellow
tab. Once the isolator is removed, the control panel will announce the sensor's
status, such as "Zone 1 Sensor 1 Triggered", and corresponding zone LED will
flash and buzzer will beep. If the magnetic contact is closed, the beeping will stop.

Note:
- Both Window/Door Sensors have been programmed at the factory. They are

Zone 1 Sensor 1 and Zone 2 Sensor 1. Trigger the sensor and listen to the
announcement to determine which one is zone 1 and which is zone 2.

Testing:
After mounting the sensor, test the sensor by opening and closing the door or
window. Open the door or window will result in the followng:

1. Voice announcement - Announce the triggered zone and sensor
2. Beeping - The number of beep represents the zone number
3. Zone LED flashing - Number of flash represents the sensor number.

Mounting the Sensor

The transmitters should be mounted on the door frame or window frame by
double sided tape. The magnet should be mounted on the door or window by
either double sided tape or screws. Make sure the magnet is aligned with the
red marking on the transmitter. If the surface of the frame is flat enough, double-
sided foam tape is sufficient, otherwise, it is recommended to screw the
mounting plate to the frame, then apply double sided tape. After mounting the
sensor, if the AAA+ logo is inverted, remove the front cover and rotate it so the
AAA+ logo is in the upright position.

INSTALLATION

Installing Door / Window Sensors

Transmitter

Magnet

Double-sided
foam tape

Mounting plate
and screws
(optional)

Sensor

Sensor

Sensor

Magnet

Magnet

"Red Marking"

"Red Marking"

Magnet on the left

Magnet on the right

HOME AUTOMATION

Part 2 Erase communication from Control Panel to Control Module

ZONE LED

DESCRIPTION

Off

Zone is not occupied by any control module

Flashes twice

That means a remote has occupied that zone.
THIS IS NOT A CONTROL MODULE, THEREFORE, SHOULD NOT BE
ERASED.

Flashes once

That zone is occupied by a control module. You may select this
zone to erase this control module.

Flashes once,

That means this zone is occupied by a remote AND a control module.

then twice

You may select this zone to erase the control module.

** Table F: Zone LED status for erasing control module.

1

2

Enter program-
ming mode

Enter master
password to
programming
mode

3 beeps for valid
password. 1 long
beep for invalid
password.

To erase the
memory of the
control module

Control module LED
will flash rapidly
indicating all the
memory is erased.
You may now
release the learn
button.

Remove the
control module
from the
electrical outlet

Press and hold
the learn button
on the control
module while
plugging in the
control module
to an electrical
outlet.

Once the memory of the control module is erased, all of its memory is cleared. If
you have other remotes / control panels controlling this control module, you need
to re-program those remotes / control panels.

Step

Keys

Function

Description

Note

41