Communication, Advanced programming – Skylink AM-100 User Manual

Page 26

Advertising
background image

Remote Operation by Telephone

The control panel can be operated while you are away from home. You can
have access to the control panel with any touch tone phone to perform a variety
of operations, listed below.

-

Arm

-

Disarm

-

Lights, Home Applicances on / off (Requires additonal Control Module)

-

Garage door open / close (Requires additional Garage Door Receiver)

-

System status

-

Disconnect

There are 2 ways you can have access to the remote phone operation:

1. You can call the control panel when you are away from home; or
2. When the control panel calls you during emergency.

COMMUNICATION

To access the control panel away from home

Calling in when you are away from home

1. Call your home phone number, or the number that the phone line of the control

panel is connected to.

2. Hang up after the second ring.

3. Wait at least 10 seconds, but not more than 40 seconds, then call the phone

number again.

4. The control panel will pick up the phone call and request for a valid user

password, you will hear “Enter Password”.

You can enter either the Master

Password or Secondary Password. If the password is correct, you will hear
“Password Accepted”, otherwise, you will hear “Password Failure”.

5. Once the password is accepted, you can have access to all the operations

listed below.

24

ADVANCED PROGRAMMING

Auto Mute

When a sensor is triggered in alert mode, audio warning will be emitted, either
beep or alarm. For example, if a door is opened, the beep will not stop until the
door is closed. If the door is open for 2 hours, the beep will go on for 2 hours.
There are times that this is not desired. With the auto mute feature enabled, the
beep will go on for only 20 seconds. After that, even if the sensor remains open,
the beep will stop only the zone LED will flash to indicate the sensor is triggered.
Beep will go on again if the sensor is closed and opened again.

Note: Auto Mute only functions when the control panel is in alert mode (disarmed).
If the control panel is in alarm mode (armed), a triggered sensor will result in
entry delay or instant alarm.

Factory Default: This feature was disabled for all zones at the factory.

To enable auto mute feature, follow the instructions below.

1

2

3

4

[PROG]
[MPIN]

Enter Program-
ming mode

Enter master
password to
programming mode

3 beeps for valid
password. 1 long beep
for invalid password.

[6]

Select Auto Mute
Enable / Disable

After [6] is entered, some
zone LEDs will flash or
stay on. This indicates
whether Auto Mute is
enabled or disabled.

Disable
Auto Mute:
[1] to [5]

Enable
Auto Mute:
[6] to [0].

Select which
zone you would
like to enable /
disable auto mute.

Refer to the diagram
below to select the
appropriate setting.

If auto mute is enabled,
that zone LED will be on.
If it is disabled, the LED
will flash. You are allow
to make multiple changes
before terminating
programming mode.

[PROG]
when
finished.

Terminate
programming
mode.

PROG LED will be off, and
you will hear 3 beeps.

Step

Keys

Function

Description

Note

29

Advertising