37

Others

The rated lamp life is about 1000 hours. The rated lamp life is the average life of the lamps produced and tested (under the
test conditions of our company). However, it may become shorter depending on the conditions of usage.
After the lamp has been operating for 1000 hours or longer, the STATUS indicator on the control panel will light and the “LAMP
USAGE” icon which shows hours of total lamp usage will be displayed on the screen. When this happens, turn off the unit and
replace the lamp cage with a new one. The unit will not turn on after 1100 hours. (It will go off if it is in use.)

Removing and installing the lamp unit

CAUTION

• Be sure to remove the lamp cage by the handle. Be sure not to touch the glass surface of the lamp cage or the inside of the projector.
• Do not loosen any screws except for those mentioned in the instructions below. There is danger of electric shock.
• To avoid injury to yourself and damage to the lamp, be sure to carefully follow the steps below.

Replacing the Projection Lamp

Reset the lamp usage timer after replacing the lamp. See page 29 for information.

• When the lamp usage timer reaches 1100 hours, it becomes impossible to turn on the power and menus are not displayed. In such a case,

see “When the lamp usage timer has exceeds 1100 hours and the unit will not turn on” on page 29.

• Obtain a replacement lamp cage at the store where the unit was purchased. Please specify the following information when ordering a

replacement lamp cartridge:

– Model name : BQC-PGM10X//-1

4

6

Remove the lamp
cage.

5

Replace the lamp cage
(after changing the lamp).

1

3

Turn off the power.

2

Disconnect the power
cord.

Unplug the power cord from the
AC socket. Wait at least one hour
after power cord is disconnected.

Open the lamp cage
cover.

Close the lamp cage
cover.

Close the lamp cage cover in the
direction of the arrow. Then
fasten the user service screw.

Unfasten the three securing
screws on the lamp cage. Hold
the lamp cage by the handle and
pull it upward.

Turn over the projector and un-
fasten the user service screw that
secures the lamp cage cover.
Then open the cover in the direc-
tion of the arrow.

Press the POWER ON/OFF button.
Wait until the cooling fan stops.

Press the lamp cage firmly into
the lamp cage compartment.
Fasten the securing screws.

Securing
screws

User service screw

User service
screw

MOUSE

ON/OFF

VIDEO

MENU

DIGITAL MULTIMEDIA

PROJECTOR

R-CLICK/EXIT

COMPUTER

ON/OFF

AUT

O S

YNC

INP

UT S

ELE

CT

ON/

OFF

POW

ER

OPE

N

STA

TUS

PG-

M10

X

FOC

US

ON/OFF

or

CAUTION:
Potential hazard of glass particles if lamp has ruptured. Please have Sharp Authorized LCD Projector Dealer or

Service Center replace lamp if rupture occurs.

Do not remove the lamp cage directly after operation of the projector. The lamp may be extremely hot. Wait at

least one hour after the power cord is disconnected to allow the surface of the lamp cage to fully cool before