Cable length subtraction, Cable length subtraction -13, Table 4-4. scsi cable length subtraction -13 – StorageTek 9710 User Manual

Page 53

Advertising
background image

MR0012J

9710 System Assurance Guide

4-13

SCSI Cabling

Cable Length Subtraction

When considering the length of an external SCSI interface bus, you must
subtract the length of bus already inside the 9710 from the maximum allowed
cable length. The individual cable measurements inside the 9710 are:

From I/O tower to drive: 1.2 m (4 ft)

Daisy chains between drives: 0.5 m (18 in.) each

From I/O tower to library control: 2.4 m (8 ft)

From drive to library control (library control can be daisy chained from the
drive data bus):

-

0.5 m (18 in.), or

-

1.2 m (4 ft), or

-

1.8 m (6 ft)

The total length of cable that must be subtracted from each bus is shown in

Table 4-4

. For the IBM AS/400 system, always subtract 1.2 m (4 ft) from the

control or data bus. The AS/400 does not allow daisy chains.

Table 4-4. SCSI Cable Length Subtraction

Number of drives on
the same data bus

Are data and control on
the same bus? (Yes/No)

Subtract this value from
maximum allowed cable length

1 (always 1 for AS/400)

no (always no for AS/400)

1.2 m (4.0 ft) from drive bus
2.4 m (8.0 ft) from control bus

2

no

1.7 m (5.5 ft) from drive bus
2.4 m (8.0 ft) from control bus

3

no

2.1 m (7.0 ft) from drive bus
2.4 m (8.0 ft) from control bus

4

no

2.6 m (8.5 ft) from drive bus
2.4 m (8.0 ft) from control bus

5

no

3 m (10.0 ft) from drive bus
2.4 m (8.0 ft) from control bus

6

no

3.5 m (11.5 ft) from drive bus
2.4 m (8.0 ft) from control bus

7

no

4 m (13.0 ft) from drive bus
2.4 m (8.0 ft) from control bus

8

no

4.4 m (14.5 ft) from drive bus
2.4 m (8.0 ft) from control bus

9

no

5 m (16.0 ft) from drive bus
2.4 m (8.0 ft) from control bus

Advertising