To unmount indoor unit

Press the 2

marks on the lower part of the indoor unit

and unlatch the tabs. Then lift the indoor unit and

unmount. (Fig. 42)

3-10. Drain Hose

a)

The drain hose should be slanted downward to the

outdoors. (Fig. 43)

b)

Never form a trap in the course of the hose.

c)

If the drain hose will run in the room, insulate the

hose with insulation* so that chilled condensation
will not damage furniture or floors. (Fig. 44)

* Foamed polyethylene or its equivalent is recom-

mended.

WARNING

Risk of Electric Shock

Do not supply power to the

unit or operate it until all

tubing and wiring to the out-

side unit are completed.

Condensation

Insulation material
(Locally purchased)
must be used.

Fig. 44

Push

Fig. 42

Slant

Drain
hose

Indoor
unit

Fig. 43