8. Address Switch

8-1. Address Setting of the Remote Control Unit

The address can be set in order to prevent interference

between remote controllers when two Sanyo indoor units

are installed near each other. The address is

normally set to “A.” To set a different address, it is

necessary to change the address on the second remote

controller.

Once changed, you cannot restore the original address

setting of the air conditioner.

(1) Switch on the power source.

(2) Break the address-setting tab marked “A” on the

second remote controller to change the address

(Fig. 62). When the tab is removed, the address is

automatically set to B (Fig. 63).

(3) Press and hold the remote controller ION button and

1 HR TIMER button. At the same time, press the

ACL(reset) button. Use a thin object such as the tip

of a pen to press the ACL button. When this has

been done, “oP-1” (test run) appears, blinking, in the

remote controller clock display area.

(4) Each time the 1 HR TIMER button is pressed, the

display changes as shown below. Press this button

2 times to change the display to “oP-7” (address

setting). (Fig. 64)

(5) “oP-7” has now been selected for address setting.

(6) Press the ON/OFF operation button on the remote

controller. (Fig. 64) Check that the “beep”signal-

received sound is heard from the second indoor unit

(approximately 5 times). The sound you hear is the

signal that the remote controller address has been

changed.

(7) Finally press the remote controller ACL (reset) but-

ton to cancel the blinking “oP-7” display.

(Fig. 64)

Changing of the second remote controller address is

now completed.

Test run mode

Selfdiagnostic mode

Address setting mode

NOTE

Fig. 62

Fig. 63

Fig. 64

Tab

ACL button

1HR.
TIMER

ON/OFF
operation

ACL
(Reset)

ION

button

button

button

button

07-154 CL1872-2472 6/12/07 3:19 PM Page 27

Advertising
This manual is related to the following products: