Appendix 3: rs-485 command set – Speco Technologies DVR-16/IP User Manual

Page 43

Advertising
background image

42

Appendix 3: RS-485 Command Set

The texts of Data 0, 1 is in ASCII code format (Normal Command)

Command OP_code Data

0,1

Note

Channel select

“01” ~ ”0G”

Channel 1~16

Right “MR”

Screen mode select

Left “ML”

Detail setting must
reference User’s manual

Sequence

“S1” ~ ”S3”

Sequence 1~3

Up key

“DU”

Down key

“DD”

Left key

“DL”

Right key

“DR”

Zoom/Enter “DZ”

Play key

“KV”

Freeze/Pause “KA”

Set “KS”

ESC “KE”

List “KL”

Date/Time “SD”

Title “ST”

Menu “SP”

Key Lock

“SK”

Lock/ Un_Locked

Goto “SR”

Fast Rewind

“RW”

x1,x2,x4,x8

Fast Forward

“FF”

x1,x2,x4,x8

Universal End

A0H

“UE”

Goto Time1

BDH

Data1, Data0

Year & Month

Goto Time2

BEH

Data1, Data0

Day & Hour

Goto Time3

BFH

Data1, Data0

Minute & “G”

PS: Goto Time1: Year=00~99 (it means 2000~2099); Month=01~12
Goto Time2: Day=01~31; Hour=00~23
Goto Time3: Minute=00~59; “G” ASCII=47H

Example:

If the Keyboard ID is 00H, the DVR-16/IP ID is E0H.
If you want to select camera 0 on the main monitor, you can use ‘01’ command.
(The ASCII Code of ‘

01

’ is 30H & 31H.)

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Receiver ID

Transmitter

ID

OP Code

Data0

Data1

Checksum

E0H 00H A0H 30H

31H 41H

NOTE:

1. The time interval between byte and byte must be shorter than 2ms, and the time interval

between 2 commands (6 bytes/command) must be longer than 2ms.

2. Checksum = Byte1 .xor. Byte2 .xor. Byte3 .xor. Byte4 .xor. Byte5