MC.31xx Manual

Channel Trigger

Trigger modes and appendant registers

Channel window trigger for entering signals

The analog input is continuously sampled with the selected
sample rate. The upper and the lower level define a win-
dow. Every time the signal enters the the window from the
outside, a triggerevent will be detected.

Channel window trigger for leaving signals

The analog input is continuously sampled with the selected
sample rate. The upper and the lower level define a win-
dow. Every time the signal leaves the the window from the
inside, a triggerevent will be detected.

Register

Value

Direction

set to

Value

SPC_TRIGGERMODE

40000

r/w

TM_CHANNEL

20040

SPC_TRIGGERMODE0

40200

r/w

TM_CHXWINENTER

10040

SPC_HIGHLEVEL0

42000

r/w

Sets the window’s upper level relatively to the channel’s input range.

board dependant

SPC_LOWLEVEL0

42100

r/w

Sets the window’s lower level relatively to the channel’s input range.

board dependant

Register

Value

Direction

set to

Value

SPC_TRIGGERMODE

40000

r/w

TM_CHANNEL

20040

SPC_TRIGGERMODE0

40200

r/w

TM_CHXWINLEAVE

10050

SPC_HIGHLEVEL0

42000

r/w

Sets the window’s upper level relatively to the channel’s input range.

board dependant

SPC_LOWLEVEL0

42100

r/w

Sets the window’s lower level relatively to the channel’s input range.

board dependant