SpectraLink Link 150 M3 MCU User Manual

Page 27

Advertising
background image

SpectraLink Corporation

Installation and Operation

Link WTS – Link 150 M3 MCU

Switch Interface

Line LEDs

MCU Type

Notes

Analog

1

SCA5xx

The SCA will only support Analog.

Comdial 3

SCU5xx

DEFINITY – Two-wire

1, 4

SCU5xx

DEFINITY – Four-wire

1, 5

SCF5xx Four-wire

Interface.

Executone

2, 5

SCB5xx

The SCB will only support Executone.

Fujitsu 2,

4

SCU5xx

Inter-Tel

2, 3, 4

SCU5xx

Meridian 1,

2

SCU5xx

Merlin Legend

1, 3

SCF5xx

Four-wire Interface.

Mitel

1, 2, 3

SCX5xx

The SCX will only support Mitel.

NEC

1, 2, 4

SCU5xx

Norstar 2

SCU5xx

Panasonic

5

SCP5xx

The SCX will only support Panasonic.

Siemens / Rolm

4

SCU5xx

Toshiba 2,

3

SCU5xx

Unconfigured

1 through 8

6. Move the mode switch back to

NORMAL

.

7. The MCU will cycle through diagnostic testing. When the system is ready for use,

the

ERROR

LED should be off, and the LED for the MCU Number (

1

to

4

) will

be lit. This should take less than two minutes.
If the LED for the MCU ID does not light, or if an MCU ID is duplicated, there
is most likely a problem with the IPC cabling. If the system displays an error
refer to section 9.1 Troubleshoot Error Codes.

8. If you select a switch type that is not supported by the MCU type, the system will

alarm. The

ERROR

LED will flash along with

STATUS

LEDs

4

and

5

. For

example, this alarm will display if you assign switch type NEC to an SCB-5XX –
Executone MCU.
If this alarm displays, use the table above to verify that your MCU type supports
the selected switch type. If you need to change the switch type, repeat steps 2
through 6.

PN: 72-0075-01-F.doc

Page 27

Advertising